Riello UPS System Sentryum Rack 60kVA SRM 60 PWC

Riello UPS stock levels are limited at the moment. Please call us before placing an order.

Riello UPS System Sentryum Rack 60kVA SRM 60 PWC power module for installation in Sentryum Rack  Cabinet. Three phase input/Three phase output. Fitted with parallel card and dual input as standard.

Compatible with industrial environments
The basic building block is a 60 kVA/kW module.

Unsure if a 20kVA UPS is right for you? Click here for our guide.

Riello UPS System Sentryum Rack 60kVA SRM 60 PWC is a transformerless online 60kVA UPS designed specifically for critical industrial applications and other settings prone to harsh environmental conditions (i.e. dust, humidity, chemical particles)

Riello UPS System Sentryum Rack 60kVA SRM 60 PWC Information

Riello UPS Sentryum Rack SRT 20 PM SA
MODULAR PLUG & PLAY SOLUTION

Riello UPS System Sentryum Rack 60kVA SRM 60 PWC can be purchased as a single 60 kVA/kW module and installed in a 19-inch rack cabinet. Another way is to lean the module on the right side; the display can be rotated 90° counterclockwise. It is also possible to remove the display (maximum 2 meters) in case the module is fitted inside a cabinet.

SMART BATTERY MANAGEMENT

The Smart Battery Management system, compatible with Li-Ion batteries and supercapacitors, consists of a series of features and capabilities to optimise battery management and obtain the best performance and operating life possible.

ADVANCED COMMUNICATIONS

60kVA Sentryum Rack module is equipped with a coloured graphic touch screen display providing UPS information,  measurements, operating states and alarms in different languages.


Extra Info

Riello UPS System Sentryum Rack 60kVA SRM 60 PWC features a unique control system that provides filtering and power factor correction upstream of the UPS, reducing harmonic distortion (<1% at resistive load and < 1.5% at non-linear load).

It has the capacity to handle high short circuits (i.e. 150% for 300 msec) and overloads (i.e. 150% for 1 minute), ensuring the UPS can deal with sudden peak loads without the need to transfer to bypass.

Riello UPS System Sentryum Rack 60kVA SRM 60 PWC comes with ‘Cold Start’ functionality that enables the UPS to start from battery power if there’s an issue with the mains supply.

• High adaptability to the input voltage
• Compatible with industrial environments
• Modular Plug & Play solution
• Suitable for stand alone and modular installations
• Complete flexibility
• Graphic touch screen display

MODELS Single-phase output (SRM)

from 20 kVA/kW to 160 kVA/kW

Three-phase output (SRT)

from 20 kVA/kW to 160 kVA/kW

INPUT
Rated voltage [V] 220 / 230 / 240 single-phase + N and 380 / 400 / 415 three-phase + N
Rated frequency [Hz] 50 / 60
Voltage tolerance [V] 230 / 400 ±20% @ full load1
Frequency tolerance [Hz] 40 - 72
Power factor @ full load 0.99
Current distortion THDI ≤3%
BYPASS
Rated voltage [V] 220 / 230 / 240 single-phase + N 380 / 400 / 415 three-phase + N
Number of phases 1 + N 3 + N
Voltage tolerance (ph-N) [V] from 180 (adjustable 180-200) to 264 (adjustable 250-264) referring to neutral
Rated frequency [Hz] 50 or 60 (selectable)
Frequency tolerance ±5% (selectable)
Bypass overload 110% infinite, 125% for 60 min, 150% for 10 min
OUTPUT
Nominal power [kVA] 20
Active power [kW] 20
Power factor 1 up to 40 °C
Number of phases 1 + N 3 + N
Rated voltage [V] 2201 / 230 / 240 single-phase + N (selectable) 3801 / 400 / 415 three-phase + N (selectable)
Rated frequency [Hz] 50 or 60
Frequency stability on battery operation 0.01%
Voltage stability ±1%
Dynamic stability EN 62040-3 class performance 1 non-linear load
Voltage distortion <1% with resistive linear load / ≤1.5% with non-linear load
BATTERIES
Type VRLA AGM/GEL/NiCd/Li-ion/SuperCaps
Recharging method One level, Two level, Cyclic recharge (selectable)
OVERALL SPECIFICATIONS
Weight of the Power Module [kg] 41
Dimensions of the Power Module (WxDxH) [mm] 445(19”)x664x397(9U)
Weight of the cabinet [kg] 165 (Power Modules excluded)
Dimensions of the

cabinet (WxDxH) [mm]

700x750x2060 (if provided by Riello UPS)
Maximum number of Power Modules for cabinet 3
Communications for each Power Module UPS status led bar - 5 inch graphic touch screen display - 2 slots for communications interface

USB - RS232 - Contact interface with 5x opto insulated Input and 4x Output relays

Ambient temperature

for the Power Module

0 °C - +40 °C
Recommended temperature for battery life +20 °C - +25 °C
Range of relative humidity 5-95% non-condensing
Colour RAL 9005
Noise level at 1 m [dBA ±2]

SMART ACTIVE

<40 for the single power module
IP rating IP20
SMART ACTIVE efficiency up to 99%
Standards European directives: LV 2014/35/EU low voltage Directive EMC 2014/30/EU electromagnetic compatibility

Directive Standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2; RoHS compliant

Classification in accordance with IEC EN 62040-3 (Voltage Frequency Independent) VFI - SS - 111

Moving the parts Pallet jack (UPS cabinet) - 2 operators (UPS Power Module
Price Promise
We always aim to be competitive and will look to beat any existing quotation you may have.
Please email or call us today.
info@cppsales.com
Book a site survey
To discuss your power protection requirements, or to arrange a site survey, please click the button below to contact us or to complete a form.
Contact us today
© Computer Power Protection 2024 All rights reserved
Top crossmenu